Topic/Presenter: Focal Plane Array / Jon Morse Question/Comment: What are the supposed readout rates/readout noise expectations for the detector controller? Readout modes... Submitted by: Jon Holtzman NIC-FPS Response: The H-1RG QE spec is >65% over 1-2.45 mu (goal of >80%); the read noise spec is <20 e- rms CDS for "slow" read mode (goal of <10 e- rms CDS); the dark rate spec is 0.1 e-/s/pix (goal of 0.01 e-/s/pix); and the spec for defects is >95% operability (goal of >98%). An array flatness spec is not included but will be characterized upon cool-down by Rockwell, and should be handled within our camera depth of focus. The H-1RG supports read-out modes of 100-200 kHz (slow mode) and 5 MHz (fast mode). The fast mode has selectable gains (from x1 - 16). In addition, the H1RG can be programmed to read out a selectable "postage stamp" sub-array at a different rate than the rest of the array. (The "G" in H-1RG stands for "Guide mode".) Resets can be done in a sequential CDS (ripple) row-by-row mode, in an instantaneous (global) mode, or pixel-by-pixel. Four columns of reference pixels are located around the perimeter of the array (the "R" in H-1RG). Status: Closed.