Summary |
|
Part
name: |
1650.1/5.5 BARR
ED090-1 |
|
|
|
|
|
|
Measurement: All parts are measured at 4 points. Once at Center and
then at three points near the edge. In an f/8 beam at AOI=0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Measured 77K shift for T%: |
-4.88558 |
|
|
|
|
|
|
|
|
|
Measured 77K shift for CWL: |
0.15 |
|
|
|
|
|
|
|
|
|
Measured 77K shift for FWHM: |
0.1 |
|
|
|
|
|
|
|
|
|
Theoretical
AOI shift 0º-5º: |
1.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(following
table represents filter data at 77K & AOI = 5 degrees, ALL RAW DATA in
worksheets attached)) |
|
|
|
Position |
center |
edge1 |
edge2 |
edge3 |
STATUS |
|
|
|
|
|
|
|
T% |
81.93 |
81.08 |
81.14 |
81.27 |
PASS |
|
|
|
|
|
|
|
CWL(nm) |
1650.35 |
1650.15 |
1650.25 |
1649.95 |
PASS |
|
|
|
|
|
|
|
FWHM(nm) |
5.3 |
5.3 |
5.3 |
5.3 |
PASS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|